Breast Implants Research - Silicone Implant, Breast Augmentation, Surgery, Risks

Breast Implants Research Today is a free monthly online journal that collates and summarizes the latest research about Breast Implants, including details on silicone implant, breast augmentation, surgery, risks.


Breast Implants Research Today

Home

View Latest Issue

Information About Breast Implants

Books on Breast Implants

Advertising in Research Today

View Other Research Today Publications



Do metallic ports in tissue expanders affect postmastectomy radiation delivery?

Damast S, Beal K, Ballangrud A, Losasso TJ, Cordeiro PG, Disa JJ, Hong L, McCormick BL

Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA.

PURPOSE: Postmastectomy radiation therapy (PMRT) is often delivered to patients with permanent breast implants. On occasion, patients are irradiated with a tissue expander (TE) in place before their permanent implant exchange. Because of concern of potential under-dosing in these patients, we examined the dosimetric effects of the Magna-Site (Santa Barbara, CA) metallic port that is present in certain TEs. METHODS AND MATERIALS: We performed ex vivo film dosimetry with single 6-MV and 15-MV photon beams on a water phantom containing a Magna-Site disc in two orientations. Additionally, using in vivo films, we measured the exit dose from 1 patient's TE-reconstructed breast during chest wall treatment with 15-MV tangent beams. Finally, we placed thermoluminescent dosimeters (TLDs) on 6 patients with TEs who received PMRT delivered with 15-MV tangent beams. RESULTS: Phantom film dosimetry revealed decreased transmission in the region of the Magna-Site, particularly with the magnet in the parallel orientation (at 22 mm: 78% transmission with 6 MV, 84% transmission with 15 MV). The transmission measured by in vivo films during single beam treatment concurred with ex vivo results. TLD data showed acceptable variation in median dose to the skin (86-101% prescription dose). CONCLUSION: Because of potential dosimetric effects of the Magna-Site, it is preferable to treat PMRT patients with permanent implants. However, it is not unreasonable to treat with a TE because the volume of tissue affected by attenuation from the Magna-Site is small. In this scenario, we recommend using 15 MV photons with compensating bolus.

Published 14 August 2006 in Int J Radiat Oncol Biol Phys, 66(1): 305-10.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Breast Implants Research Today. All Rights Reserved.



Breast Implants Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)



Breast Implants Books

Breast Implants: Everything You Need to Know

Breast Implants: Everything You Need to Know